TIMFRSTOP 60-Minute Fire-Rated Cavity Stop Sock Timber-Masonry

TIMFRSTOP 60-minute fire-rated cavity stop sock for timber-to-masonry construction. Designed to:

  • Restrict the spread of smoke and flames within external timber-masonry cavity walls
  • Provide a cavity barrier at separating walls, separating floors and around window or door apertures
  • Minimise heat loss and effect of flanking noise pollution through the cavity wall

Independently tested by Warringtonfire in accordance with EN1366-4 principles

BIM Objects

We have partnered with the BIMstore to help provide you with the highest standard of BIM content around.

Browse BIM Information

Product Information

Product CodeTo Suit Cavity WidthDimensionsMinimum CompressionBag ColourPack QuantityPallet Quantity
TIMFRSTOP5050mm65 x 65 x 1200mm15mmRed20240
TIMFRSTOP6551-65mm85 x 75 x 1200mm20mmRed18216
TIMFRSTOP7566-75mm100 x 75 x 1200mm25mmRed12144
TIMFRSTOP8576-85mm100 x 150 x 1200mm15mmYellowNA102
TIMFRSTOP9086-90mm110 x 150 x 1200mm20mmYellowNA90
TIMFRSTOP10091-100mm120 x 150 x 1200mm20mmYellowNA90
TIMFRSTOP115101-115mm130 x 150 x 1200mm15mmYellowNA72
TIMFRSTOP125116-125mm140 x 150 x 1200mm15mmYellowNA72
TIMFRSTOP130126-130mm150 x 150 x 1200mm20mmYellowNA66
TIMFRSTOP140131-140mm160 x 150 x 1200mm20mmYellowNA60
TIMFRSTOP150141-150mm160 x 150 x 1200mm10mmYellowNA60

*Pallet quantities may vary slightly from the values stated above. Contact Timloc Sales for confirmation.

  • TIMFRSTOP cavity stop socks comprise a length of non-combustible mineral wool insulation sleeved in a polythene outer layer for on-site weather protection
  • 60-minute fire integrity and insulation performance
  • Available to suit cavity widths from 50mm up to 150mm
  • Complies with Building regulations Approved Document B and Robust Detail part E
  • Independently tested by Warringtonfire in accordance with EN1366-4 principles
  • Satisfies NHBC technical requirements
  • Manufactured using mineral wool insulation classified as Euroclass A1 for fire according to BS EN 13501-1
  • Mineral wool insulation is compliant with BS EN 13162 Thermal insulation products for buildings, ISO 50001 Energy Management Systems, ISO 14001 Environmental Management Systems and ISO 9001 Quality Management Systems
  • The product contains no CFCs, HCFCs, or other ozone-depleting substances
  • The thermal conductivity of the Mineral wool insulation is 0.037 W/mK
  • Supplied in 1200mm lengths
  • For individual product colours refer to the product code table

TIMFRSTOP can be installed via one of two methods:

 

A) Direct fix via polythene flanges to the timber frame:

  • Secure each length of TIMFRSTOP to the timber frame through the polythene flanges with clout nails or staples spaced 150mm apart
  • To install in the vertical direction apply nails or staples to the flanges on both sides of the product
  • To install in the horizontal direction apply nails or staples to the flange on the top edge of the product only
  • The construction of the outer leaf can then be completed, ensuring that the cavity width is correct and maintains compression to the TIMFRSTOP lengths

B) Compression fit between inner and outer leaf as work progresses upwards:

  • Build up the inner and outer leaf to the level at which the TIMFRSTOP will be situated
  • Check that the cavity width is correct to specification and will provide a compression fit onto the TIMFRSTOP lengths
  • Ensure that the mortar of the brick work is set then insert the TIMFRSTOP lengths into the cavity between the inner and outer leaf

General Installation Notes

  • Ensure that the TIMFRSTOP lengths fully fill the cavity with an even amount of compression on both sides
  • At junctions or when cutting down is required, the lengths of TIMFRSTOP should be cut to the appropriate length and butt jointed firmly to the next length or to the supporting construction
  • When trimming the lengths any excess polythene should also be trimmed and folded back over to maintain the site weather protection.
  • Do not bend or deform the lengths to fit into the cavity around corners or junctions as this will damage the mineral wool insulation
  • The polythene outer layer does not contribute to the fire rating of the TIMFRSTOP it is only used to aid the installation via the flanges and provide site weather protection. If the polythene becomes pierced or torn the stop sock will still function as intended
  • If the mineral wool insulation in one of the TIMFRSTOP lengths is broken or damaged before installation, then it should be discarded and replaced with another undamaged length
  • When installed horizontally a preformed horizontal cavity tray should be incorporated into the cavity wall construction (refer to technical department for the appropriate type to suit) and proprietary wall weep vents (E.g. Timloc 1143) spaced at 900mm centres to prevent water ingress from bridging the cavity

F30 Accessories/sundry items for brick/block/stone walling
Clause
370 PREFORMED CAVITY TRAY / ACCESSORIES

  • Manufacturer: Timloc Building Products, Timloc House, Ozone Park, Howden, East Yorks. DN14 7SD. T: 01405 765 567 W: www.timloc.co.uk
  • Reference: TIMFRSTOP
  • Types(s) and location(s): Thermal and acoustic fire stops to be installed vertically and horizontally as work proceeds. Position at separating walls, separating floors and around window or door apertures. Supplied in 1200mm lengths and butt jointed.
  • Colour: Red, Yellow

To calculate required quantities:

  • Divide the overall length of the cavity wall run (measured in mm) by 1200mm
  • Allow one additional length for each corner for trimming
  • Determine and specify the cavity width that the product needs to fit into

Latest News