Hedgepigs & Hoglets Rescue Push To Complete Their New Rescue Building
Through sales of the Hedgehog Highway by Timloc Building Products, part of Alumasc Group plc, has donated £200 worth of food and supplies to Hedgepigs & Hoglets Rescue.
BBA-approved stepped leaded cavity tray system for multi cavity options in brick wall construction of 75mm coursing heights.
Everdry preformed cavity trays are a range of DPC products for installation at the abutment of a pitched roof with a cavity wall to prevent water penetration. All Everdry cavity tray components are designed to comply fully with the requirements set out in Building Regulations, British Standards and the NHBC.
Uses:
Description | Length | Handing | Product codes to clear cavity widths of 50-110mm |
---|---|---|---|
Intermediate tray | Varies | RH | 20001 |
Intermediate tray | Varies | LH | 20002 |
Stopend starter tray | 225mm | RH/LH | 20031/32 |
Corner starter tray | 225mm | RH/LH | 20041/42 |
Ridge tray | 225mm | N/A | 20061 |
Ridge tray | 420mm | N/A | 20062 |
Trays to suit clear cavity widths of 111mm can be made to order. N.B Intermediate trays are 225mm in length at roof pitches of 27.5 degrees and above. Below this pitch the length increases to 420mm and 525mm. Please state roof pitch and whether long or short leads are required.
Intermediate trays
Suits all cavity options – forms main tray run with one tray on each course of brickwork running the full length of the abutting roof slope.
Stopend starters
First component to be installed and fitted at the lowest point on a standard abutment. It collects water gathered by the rest of the system and discharges it from the wall through a weep unit.
Corner starter trays
Has same function as stopend starter tray but is used where the abutting roof comes up to, or beyond, the corner of the main building. Designed to return around the corner of the building to provide complete protection.
Ridge trays
Used where a right-hand and left-hand roof slope come together at an apex to straddle the top two intermediate tray.
F30 Accessories/sundry items for brick/block/stone walling
Clause 370 | PREFORMED CAVITY TRAY / ACCESSORIES
Stepped cavity trays are used where a pitched roof abuts a cavity wall. To calculate the quantity of trays required to cover a section of roof abutment one of three measurements must be determined, either the vertical height or the sloping or horizontal length of the abutment. If the vertical height is measured, simply divide this distance by the coursing height of the material being used for construction. E.g. If the vertical height is 1.5m and the wall is standard 75mm brick coursing (NB 75mm = 0.075m) the equation would be 1.5 ÷ 0.075 = 20. Therefore 20 No. cavity trays are required per sloping abutment.
If the sloping or horizontal distance has been measured the tables shown below should be used to convert the distance (measured in metres) into the quantity of cavity trays. Take care to select the correct table and the appropriate column which relates to the coursing height and the pitch of the abutting roof. E.g. If the sloping measurement is 2.5m, at a pitch of 30°,with a 75mm brick coursing height the equation would be 2.5 x 6.7 = 16.75. This would be rounded up, so 17 No. cavity trays are required. E.g. If the horizontal measurement is 1.5m, at a pitch of 40°, with a 75mm brick coursing height the equation would be 1.5 x 11.2 = 16.8. This would be rounded down, so 16 No. cavity trays are required.