Z-Series Metal 1 Hour Fire Rated Hinged Loft Access Doors – 1160 & 1161

Easy-to-install hinged drop-down loft access door designed to provide easy through-ceiling access into the loft space, for use where fire protection is required. Fire-rated loft doors provide up to 60 minutes fire protection and come fully assembled and ready to fit straight out of the box. Twist operated catch to release a downward opening hinged door. Insulation U-value performances of 0.82 W/m2K and 0.35 W/m2K available.

Loft door sizes:
Z8004 – (previously 1160) – 542 x 745mm (frame fitting size)
Z8003 – (previously 1161) – 542 x 630mm (frame fitting size)

Other sizes available here. Loft door operating pole also available.

BIM Objects

We have partnered with the BIMstore to help provide you with the highest standard of BIM content around.

Browse BIM Information

Product Information

1 Hour Fire Rated Hinged Loft Access Door

DescriptionFrame fitting sizeClear opening sizeInsulation U-valueProduct Code
1 hour fire rated hinged loft door542 x 745mm520 x 695mm0.82 W/m2kZ8004
1 hour fire rated hinged loft door with key lock542 x 745mm520 x 695mm0.82 W/m2kZKL8004
1 hour fire rated hinged loft door542 x 745mm520 x 695mm0.35 W/m2kZ9004
1 hour fire rated hinged loft door with key lock542 x 745mm520 x 695mm0.35 W/m2kZKL9004
1 hour fire rated hinged loft door542 x 630mm520 x 580mm0.82 W/m2kZ8003
1 hour fire rated hinged loft door with key lock542 x 630mm520 x 580mm0.82 W/m2kZKL8003
1 hour fire rated hinged loft door542 x 630mm520 x 580mm0.35 W/m2kZ9003
1 hour fire rated hinged loft door with key lock542 x 630mm520 x 580mm0.35 W/m2kZKL9003

  • Fully complies with NHBC standards for having a minimum access opening of 520mm
  • Purpose made product with proven performance
  • Superior to site fabricated panels
  • Provides up to 60 minutes fire protection and Class O surface spread of flame classification
  • Excellent aesthetic appearance and factory finished
  • Maintenance free, no need to paint
  • Allows the use of a telescopic ladder if required
  • Incorporates secure twist operated catch assembly
  • U value 0.82 W/m2k and 0.35W/m2k option
  • Acoustic performance of 29dB
  • Fire testing conducted by Warrington Fire Research Ltd
  • 0.35U value option meets Robust Details
  • Complies with Building Regulations document L1A & L2A (2013 Edition)
  • Meets all relevant British Standards and NHBC requirements
  • The frame and door are fabricated in 1mm and 1.2mm Zintec electrogalvanised mild steel. The door is lined with a fire-resistant sub-panel to enhance fire resistance and stability. Polyester powder coating, lightly textured.
  • Door and frame available in white only RAL 9016.
  • The 1160 and 1161 are designed to fit between trussed rafters or ceiling joints spaced at 600mm centres which provide a clear joist opening width of 562mm to be plasterboard lined to give 542mm.
  • If the joist spacing does not provide this opening width, a suitable trimmed opening must be formed.
  • It is essential that trimmers are installed between the ceiling joists across the ends of the frame.
  • The frame fixes with 10 screws, six into the ceiling joists at the sides of the frame, and four through the ends of the frame into the trimmers.
  • A 50mm tall by 10mm thick protective plasterboard surround is required along all four sides of the trimmed opening.

L20 Doors/Shutters/Hatches

Clause 630^ | HATCHES

  • Manufacturer: Timloc Building Products, Timloc House, Ozone Park, Howden, East Yorkshire, DN14 7SD. Tel: 01405 765567 Web: www.timloc. co.uk
  • Product reference: 1160 or 1161
  • Type: loft access door (Hinged)
  • 1160 to suit fitting 542mm x 745mm
  • + 1161 to suit fitting 542mm x 630mm
  • Specification: insulated and draught stripped
  • Colour: textured white polyester powder coating

Timloc loft access doors contain glass wool insulation with a Thermal Conductivity of 0.037W/mK. For this reason, a correction U value of 0.004W/m2k should be calculated to the proposed U value figures for a ceiling (U value for a ceiling, not to exceed 0.16W/m2k).

With reference to insulation, the products in this range do not use, contain or produce CFC’s, ie. HCFC’s & HFA’s. The mineral wool insulation relies on entrapped air for its thermal properties; air is not a VOC and it does not have Global Warming Potential (GWP) or Ozone Depletion Potential (ODP).