Tile Ventilators

A range of roof tile ventilators designed to suit most common styles of roof tiles.

The TV8 plain tile ventilator is suitable for high and low level venting in roofs with minimum pitches of 35° (clay tiles) and 40° (concrete tiles).

The TV62 profiled tile ventilator comes in a range of profiles designed to most common styles of interlocking roof tiles.

The Timloc range of tile vents meets requirements of Building Regulations Approved Document Part F1, Part F2 and BS5250: 2011 ‘ Code of practice for control of condensation in buildings’.

Use:

  • To provide inconspicuous ventilation to suit most types of roof tiles
  • Suitable for high- or low-level venting 
  • Can be used for mechanical extraction or with soil pipes

Product Information

Available in Terracotta, red, sepia and anthracite

DescriptionSuitable forProduct Code
Inline plain tile ventilatorTV8*
Inline plain tile ventilatorMarley Mendip Redland Grovebury and similar profilesTV62MEN*
Inline profiled tile ventilatorMarley Modern Russell Grampian Redland Mini Stoneworld and similar profilesTV62MDA*
Inline profiled tile ventilatorMarley Ludlow Major and similar profilesTV62MLM*
Inline profiled tile ventilatorMarley Double Roman Russell Double Roman Redland Landmark Double Roman Sandtoft Double Roman and similar profilesTV62FRA*

* Include colour choice option (TE=Terracotta, RE=Red, SE=Sepia, AN=Anthracite)

  • High performance while retaining the aesthetics of roof design 
  • Suitable for use with a wide range of roof tile profiles 
  • Range of standard colours and profiles 
  • UV stable for continuous exposure
  • Quick to install, requiring no special tools or maintenance
  • Satisfies all NHBC requirements
  • Meets requirements of Building Regulations Approved Document Part F1, Part F2 and BS 5250:2011 ‘Code of practice for control of condensation in buildings’
  • TV8 in PVC-u. TV62 in polypropylene.
  • Available in terracotta, red, sepia, and anthracite.
  • TV8 plain tile ventilator 
    • For small, non- interlocking clay and concrete plain tiles. It is suitable for high/low level venting in roofs with minimum pitches of 35° (clay tiles) and 40° (concrete tiles). 
    • Each vent has a slotted inhibitor to keep out large insects and vermin and requires a minimum of batten and tile trimming during installation.
    • Free vent area 7500mm². 
  • TV62 profiled tile ventilator 
    • Profiles to suit most common styles of interlocking roof tiles. 
    • Suitable for high or low level venting in roofs with pitches of 22.5° and over and can be used to supplement or replace other ventilation such as dry ridge, abutment or eaves systems.
    • Also suitable for ventilation of compartmental roof spaces, such as fire walls. Free vent area 10,000 mm².
  • For TV8 a ‘V’ cut is made immediately below the batten. The “pennant” is pulled up tightly round the batten and pinned in place.
  • For TV62 at each ventilating tile position the underlay must be cut to form the required opening and its edge folded, and where necessary, supported to prevent the ingress of water. The vents are then laid and fixed by the roofer in place of an ordinary tile.
  • Determine the quantity required according to the use for which the ventilator is being put, specify the type of tile being used and the colour.

G20 Carpentry/Timber Framing/First Fixing 

Clause 900^ EAVES SOFFIT VENTILATION

  • Manufacturer: Timloc Building Products, Timloc House, Ozone Park, Howden, East Yorkshire, DN14 7SD. Tel: 01405 765567 Web: www.timloc.co.uk 
  • Product Reference: TV8/TV62 MEN etc 
  • Type: Plain Tile Ventilator/Profiled Tile Ventilator
  • To suit Tile: Plain Tile/Profiled Tile Marley etc
  • Colour: Terracotta/Red/Sepia/Anthracite