PWFRSTOP 60-Minute Fire-Rated Party Wall Cavity Stop Sock Masonry-Masonry

PWFRSTOP 60-minute fire-rated party wall cavity stop sock for masonry-to-masonry construction. Designed to:

  • Restrict the spread of smoke and flames within masonry cavity walls
  • Provide a cavity barrier at party wall junctions
  • Minimise heat loss and effect of flanking noise pollution through the cavity wall

Independently tested by Warringtonfire in accordance with EN1366-4 principles

BIM Objects

We have partnered with the BIMstore to help provide you with the highest standard of BIM content around.

Browse BIM Information

Product Information

Product CodeTo Suit Cavity WidthDimensionsMinimum CompressionBag ColourPallet Quantity
PWFRSTOP505065 x 250 x 1200mm15mmYellow80
PWFRSTOP6551-65mm85 x 250 x 1200mm20mmBlue60
PWFRSTOP7566-75mm85 x 250 x 1200mm10mmBlue60
PWFRSTOP8576-85mm100 x 250 x 1200mm15mmBlue68
PWFRSTOP9086-90mm100 x 250 x 1200mm10mmBlue68
PWFRSTOP10091-100mm110 x 250 x 1200mm10mmBlue60
PWFRSTOP115101-115mm130 x 250 x 1200mm15mmYellow52
PWFRSTOP125116-125mm140 x 250 x 1200mm15mmYellow48
PWFRSTOP130126-130mm150 x 250 x 1200mm20mmYellow48
PWFRSTOP140131-140mm160 x 250 x 1200mm20mmYellow44
PWFRSTOP150141-150mm160 x 250 x 1200mm10mmRed40
PWFRSTOP160151-160mm185 x 250 x 1200mm25mmRed36
PWFRSTOP170161-170mm195 x 250 x 1200mm25mmRed32
PWFRSTOP180171-180mm200 x 250 x 1200mm20mmRed32
PWFRSTOP190181-190mm210 x 250 x 1200mm20mmRed32
PWFRSTOP200191-200mm220 x 250 x 1200mm15mmRed28
PWFRSTOP210201-210mm230 x 250 x 1200mm20mmBlue28
PWFRSTOP220211-220mm240 x 250 x 1200mm20mmBlue28
PWFRSTOP230221-230mm250 x 250 x 1200mm20mmBlue24
PWFRSTOP240231-240mm260 x 250 x 1200mm20mmBlue24
PWFRSTOP250241-250mm270 x 250 x 1200mm20mmBlue24
PWFRSTOP260251-260mm280 x 250 x 1200mm20mmBlue24
PWFRSTOP270261-270mm290 x 250 x 1200mm20mmBlue24
PWFRSTOP280271-280mm300 x 250 x 1200mm20mmBlue20
PWFRSTOP290281-290mm310 x 250 x 1200mm20mmBlue20
PWFRSTOP300291-300mm320 x 250 x 1200mm20mmBlue20

*Pallet quantities may vary slightly from the values stated above. Contact Timloc Sales for confirmation. *Bag colour received may vary from colours stated above. Contact Timloc Technical for confirmation.

  • PWFRSTOP cavity stop socks comprise a length of non-combustible mineral wool insulation sleeved in a polythene outer layer for on-site weather protection
  • 60-minute fire integrity and insulation performance
  • Available to suit cavity widths from 50mm up to 300mm
  • Complies with Building regulations Approved Document B and Robust Detail part E
  • Independently tested by Warringtonfire in accordance with EN1366-4 principles
  • Satisfies NHBC technical requirements
  • Manufactured using mineral wool insulation classified as Euroclass A1 for fire according to BS EN 13501-1
  • Mineral wool insulation is compliant with BS EN 13162 Thermal insulation products for buildings, ISO 50001 Energy Management Systems, ISO 14001 Environmental Management Systems and ISO 9001 Quality Management Systems
  • The product contains no CFCs, HCFCs, or other ozone-depleting substances
  • The thermal conductivity of the Mineral wool insulation is 0.037 W/mK
  • Supplied in 1200mm lengths
  • For individual product colours refer to the product code table

PWFRSTOP should be installed with a compression fit between the inner and outer leaf as brick courses progress upwards

Vertical applications:

  • Firstly build up the inner leaf
  • Place the PWFRSTOP into the desired position at the party wall
  • Now build up the external leaf and check that the cavity width is correct to specification and is providing a compression fit onto the PWFRSTOP lengths

Horizontal applications:

  • Firstly build up the inner and outer leaf to the level at which the PWFRSTOP will be situated
  • Ensure that the mortar of the brick work is set then insert the PWFRSTOP lengths into the cavity between the inner leaf party wall junction and the main outer leaf

General Installation Notes

  • Ensure that the PWFRSTOP lengths fully fill the cavity with an even amount of compression on both sides
  • At junctions the lengths of PWFRSTOP should be firmly butt jointed to the next length or to the supporting construction
  • When trimming the lengths, any excess polythene should also be trimmed and folded back over to maintain the site weather protection
  • Do not bend or deform the lengths to fit into the cavity around corners or junctions as this will damage the mineral wool insulation
  • The polythene outer layer does not contribute to the fire rating of the PWFRSTOP it is only used to aid the installation and provide site weather protection. If the polythene becomes pierced or torn the stop sock will still function as intended
  • If the mineral wool insulation in one of the PWFRSTOP lengths is broken or damaged before installation then it should be discarded and replaced with another undamaged length
  • When installed horizontally a preformed horizontal cavity tray should be incorporated into the cavity wall construction (refer to technical department for the appropriate type to suit) and proprietary wall weep vents (1143) spaced at 900mm centres to prevent water ingress from bridging the cavity

F30 Accessories/sundry items for brick/block/stone walling
Clause
370 PREFORMED CAVITY TRAY / ACCESSORIES

  • Manufacturer: Timloc Building Products, Timloc House, Ozone Park, Howden, East Yorks. DN14 7SD. T: 01405 765 567 W: www.timloc.co.uk
  • Reference: PWFRSTOP
  • Types(s) and location(s): Thermal and acoustic fire stops to be installed vertically and horizontally as work proceeds. Position at party wall to cavity wall junctions or at floor level. Supplied in 1200mm lengths and butt jointed.
  • Colour: Yellow, Blue, Red

To calculate required quantities:

  • Divide the overall length of the cavity wall run (measured in mm) by 1200mm
  • Allow one additional length for each corner for trimming
  • Determine and specify the cavity width that the product needs to fit into